closed
OSD: Add heartbeat message for Jumbo Frames(MTU 9000)
Added by Vikhyat Umrao almost 7 years ago.
Updated over 6 years ago.
Description
- OSD: Add heartbeat message for Jumbo Frames(MTU 9000)
- When we have jumbo frames enabled in cluster network and if MTU is not configured properly like the recommendation is all interconnecting network gear must also have jumbo frames enabled but if any device is misconfigured for jumbo frames then we see a lot of issues like peering stuck, slow requests and backfilling not progressing.
- And the issue is we do not see heartbeat timeout messages in the OSD logs because heartbeat messages packet size is below 1500.
- We checked the communication issue with below command:
# ping -W 2 -I <interface> -M do -s <pkt size> <IP address>
Downstream feature request: https://bugzilla.redhat.com/show_bug.cgi?id=1455711
- Description updated (diff)
- Subject changed from OSD: Add heartbeat message for Jumbo Frames(MTU 900) to OSD: Add heartbeat message for Jumbo Frames(MTU 9000)
- Description updated (diff)
- Is duplicate of Feature #18438: Configurable OSD Heartbeat packet size (MTU) added
I've seen stuff about this before but not been entirely clear on what's happening. Is the issue that the local box is configured for jumbo frames but the switch silently drops them? I'm wondering if there's something Ceph can query to know if it needs to do this validation.
I suppose we can inflate the heartbeat packets with a zero-filled bufferlist or something. Should we do that for every heartbeat? I suppose a 9KB packet that gets thrown away isn't that much wasted network bandwidth...
- Description updated (diff)
Greg Farnum wrote:
Thanks Greg for your inputs.
I've seen stuff about this before but not been entirely clear on what's happening. Is the issue that the local box is configured for jumbo frames but the switch silently drops them? I'm wondering if there's something Ceph can query to know if it needs to do this validation.
Yes. This was the case. Local was having MTU configured as 9000 and there was some issue at switch layer configuration for 9000 MTU and osd does not log about heartbeat failures.
I suppose we can inflate the heartbeat packets with a zero-filled bufferlist or something. Should we do that for every heartbeat? I suppose a 9KB packet that gets thrown away isn't that much wasted network bandwidth...
Yep. Yesterday I had a quick discussion with Josh before creating this feature request and we agreed that a feature for periodically sending a larger request to detect that MTU issue would be great. Maybe we can choose periodically? `osd_heartbeat_interval` default is 6 seconds maybe we can choose even number packets?
- Status changed from New to 7
- Assignee set to Greg Farnum
- Status changed from 7 to Pending Backport
- Copied to Backport #20353: jewel: OSD: Add heartbeat message for Jumbo Frames(MTU 9000) added
Greg Farnum wrote:
Note to backporters: consider whatever happens with https://github.com/ceph/ceph/pull/15727 !
Thanks Greg. I have assigned the backport to myself. I will keep tracking of 15727 and will take action according to that.
- Status changed from Pending Backport to Resolved
Also available in: Atom