Project

General

Profile

Actions

Bug #10816

closed

"mds e5 Missing health data for MDS 4117" endless loop in upgrade:firefly-x-hammer-distro-basic-multi run

Added by Yuri Weinstein over 9 years ago. Updated about 9 years ago.

Status:
Resolved
Priority:
Urgent
Category:
-
% Done:

0%

Source:
Q/A
Tags:
Backport:
Regression:
Severity:
3 - minor
Reviewed:
Affected Versions:
ceph-qa-suite:
Crash signature (v1):
Crash signature (v2):

Actions #1

Updated by Greg Farnum over 9 years ago

  • Project changed from Ceph to teuthology
  • Assignee set to Yuri Weinstein

At a guess, you've upgraded the monitors and the MDS has not been upgraded yet. (Or some but not all of the monitors?)

This is usually going to be seen when upgrading and just means that somebody between the MDS and the leader (inclusive) isn't generating or propagating health data. It should be whitelisted.

Actions #2

Updated by Yuri Weinstein over 9 years ago

  • Assignee changed from Yuri Weinstein to Loïc Dachary
Actions #3

Updated by Loïc Dachary over 9 years ago

  • Assignee changed from Loïc Dachary to Yuri Weinstein

I can't think of a reason why erasure code would cause failure in this situation. And even if it did, I can't hink of a way for an erasure code failure to manifest itself in this way. In addition erasure code has not changed recently.

Actions #4

Updated by Yuri Weinstein over 9 years ago

  • Priority changed from Normal to Urgent
Actions #5

Updated by Yuri Weinstein over 9 years ago

  • Assignee deleted (Yuri Weinstein)
Actions