Bug #54328
openProblems using OSDSpec with DB and WAL on same NVME device
0%
Description
When provisioning a new cluster using Pacific 16.2.7, I find that in spite of using OSDSpec with cephadm for the addition of OSDs, a WAL device is not included and the WAL is instead saved on the data disks.
The data disks are HDDs, so obviously this is not desired.
Here is the output of a dry-run:
----------------------------+----------------------------------+----------+--------------+-----+
|SERVICE |NAME |HOST |DATA |DB |WAL |----------------------------+----------------------------------+----------+--------------+-----+
|osd |default_drive_group |cepho-p000 |/dev/sda |/dev/nvme1n1 |- |
|osd |default_drive_group |cepho-p000 |/dev/sdb |/dev/nvme1n1 |- |
|osd |default_drive_group |cepho-p000 |/dev/sdc |/dev/nvme1n1 |- |
|osd |default_drive_group |cepho-p000 |/dev/sdd |/dev/nvme1n1 |- |
|osd |default_drive_group |cepho-p000 |/dev/sde |/dev/nvme1n1 |- |
|osd |default_drive_group |cepho-p000 |/dev/sdf |/dev/nvme1n1 |- |
|osd |default_drive_group |cepho-p000 |/dev/sdg |/dev/nvme1n1 |- |
|osd |default_drive_group |cepho-p000 |/dev/sdh |/dev/nvme1n1 |- |
|osd |default_drive_group |cepho-p000 |/dev/sdi |/dev/nvme1n1 |- |
|osd |default_drive_group |cepho-p000 |/dev/sdj |/dev/nvme0n1 |- |
|osd |default_drive_group |cepho-p000 |/dev/sdk |/dev/nvme0n1 |- |
|osd |default_drive_group |cepho-p000 |/dev/sdl |/dev/nvme0n1 |- |
|osd |default_drive_group |cepho-p000 |/dev/sdm |/dev/nvme0n1 |- |
|osd |default_drive_group |cepho-p000 |/dev/sdn |/dev/nvme0n1 |- |
|osd |default_drive_group |cepho-p000 |/dev/sdo |/dev/nvme0n1 |- |
|osd |default_drive_group |cepho-p000 |/dev/sdp |/dev/nvme0n1 |- |
|osd |default_drive_group |cepho-p000 |/dev/sdq |/dev/nvme0n1 |- |
|osd |default_drive_group |cepho-p000 |/dev/sdr |/dev/nvme0n1 |- |----------------------------+----------------------------------+----------+--------------+-----+
Here is the OSDSpec file I used:
service_type: osd
service_id: default_drive_group
placement:
host_pattern: 'cepho-*'
spec:
data_devices:
rotational: 1
db_devices:
rotational: 0
Based on what it says at https://docs.ceph.com/en/latest/cephadm/services/osd/#the-simple-case I assumed that DB and WAL placement would be on the same non-rotational device.
I tried altering the file to include wal_devices too, but in this case it did not specify a DB device in the preview.
Hence, it appears to be offering either DB or WAL but not both.