cephadm adopt - Report conf file missing - now it says could not detect legacy fsid

Added by Vasishta Shastry about 3 years ago. Updated over 2 years ago.

Status:
Can't reproduce
Priority:
Normal
Assignee:
-
Category:
cephadm (binary)
Target version:
-
% Done:

0%

Source:
Tags:
Backport:
Regression:
No
Severity:
3 - minor
Reviewed:
Affected Versions:
ceph-qa-suite:
Pull request ID:
Crash signature (v1):
Crash signature (v2):

Description

version - cephadm-16.1.0-603.el8cp.noarch

cmd:

  - cephadm
  - --image
  - registry.redhat.io/openshift4/ose-prometheus-alertmanager:v4.6
  - adopt
  - --cluster
  - ceph
  - --name
  - alertmanager.ceph-vasishta-1615821696698-node10-grafana
  - --style
  - legacy
  - --skip-pull

Output -

stderr: 'ERROR: could not detect legacy fsid; set fsid in ceph.conf'

Actually conf file was not existing on the node

So It would be apt if we can Error out to user saying conf file doesn't exist

Actions #1

Updated by Sebastian Wagner almost 3 years ago

  • Description updated (diff)
Actions #2

Updated by Sebastian Wagner almost 3 years ago

Do you remember, were there any other ceph daemons deployed on that host? cephadm needs to know the fsid of the cluster. if there are no OSD daemons on that host or if there is no /etc/ceph/ceph.conf on that host, if won't be able to know that

Actions #3

Updated by Sebastian Wagner almost 3 years ago

  • Category set to cephadm (binary)
Actions #4

Updated by Sebastian Wagner over 2 years ago

  • Status changed from New to Can't reproduce
Actions