Project

General

Profile

Actions

Bug #41693

open

a accidental problems with osd detection algorithm in monitor

Added by shuguang wang over 4 years ago. Updated over 4 years ago.

Status:
Need More Info
Priority:
Normal
Assignee:
-
Category:
-
Target version:
-
% Done:

0%

Source:
Tags:
Backport:
Regression:
No
Severity:
3 - minor
Reviewed:
Affected Versions:
ceph-qa-suite:
Component(RADOS):
Monitor
Pull request ID:
Crash signature (v1):
Crash signature (v2):

Description

There is a accidental problems with osd detection algorithm in monitor. In a three-cluster environment,HostA/HostB/HostC,storage pool is a three-replicate mode.if HostC network failure and recovery from anomalies, the part of osd will change state from up to down in HostA or HostB.

Actions #1

Updated by Greg Farnum over 4 years ago

  • Status changed from New to Need More Info

Can you explain in more detail exactly what happened here?

It sounds like you have three hosts with colocated OSDs and monitors, triggered a net split, and then saw OSDs go down on a host you did not expect, but I'm not sure. That could easily happen depending on your monitor configuration and is not necessarily a bug.