Description

As part of characterizing RGW read performance, have observed that there is a single RADOS connection that is consumed by so many RGW worker threads, resulting in some amount of serialization at that level. Making the RADOS handles multiple, and shared across the worker threads in a RR fashion, has resulted in significant performance improvement.


Related issues

Copied to rgw - Backport #12894: Have a configurable number of RADOS handles in RGW Resolved

History

#2 Updated by Loïc Dachary over 8 years ago

  • Status changed from New to Pending Backport

#3 Updated by Nathan Cutler over 8 years ago

  • Status changed from Pending Backport to Resolved